Daylight Integrated Vertical Agriculture
Industrial Design • Product & Mechanical Development • Systems Design • Technical Research & Modeling
Self-Directed Design and Research Project | 2026
( THE CURRENT PROJECT IS BEING COMPILED FROM MY RESEARCH AND ADDED AS I COMPLETE SECTIONS)
(THANK YOU FOR YOUR PATIENCE)
Why I Chose This Project
Hydroponics interested me because of its potential to produce substantial quantities of food while using considerably less land and water than conventional agriculture. Growing crops vertically offers even greater possibilities, but I found that the benefits often come with significant operating costs. Artificial lighting, heating, cooling, and labor can make indoor agriculture expensive, raising questions about whether its resource savings are enough to justify the investment. I wanted to investigate whether those costs could be reduced by reconsidering how the entire facility is designed. Could natural daylight replace some of the electricity consumed by growing lights? Could better insulation and climate control reduce heating and cooling expenses? Could equipment be designed to simplify planting and harvesting? Most importantly, could these improvements make vertical farming both environmentally responsible and commercially competitive?
What Is TerraLumen?
TerraLumen is a proposed vertical hydroponic farming system that combines natural daylight, supplemental LED lighting, climate controlled architecture, and automated cultivation equipment. Rather than treating the building as an enclosure for growing machinery, the project develops the architecture and equipment together, examining how light, temperature, crop density, water circulation, and production operations influence one another. The research examines four independent facilities in Phoenix, Seattle, Kansas City, and Kiruna, Sweden, each designed for its local climate. Genovese basil serves as the final study crop, grown in modular four level Grow Deck racks. The project extends beyond the physical design to investigate production capacity, resource consumption, construction costs, and operating economics, including comparisons with three conventional agricultural methods. All facilities remain conceptual designs supported by engineering research and modeled financial estimates.
Rethinking Agriculture
TRADITIONAL FARMING
What I Found & Why It's a Problem
Traditional farming benefits from free sunlight, established machinery, and relatively inexpensive growing infrastructure. However, production is dependent on available land, favorable weather, and reliable water supplies. Many crops are particularly sensitive to cold temperatures, limiting their outdoor growing season in many regions. The TerraLumen comparison modeled between one and five annual basil cuttings across the four climates, relative to the grow season for each climate, illustrating how geographic conditions affect production opportunities. Irrigation requirements, pesticides, crop losses, and the need for extensive labor can further influence profitability and operating costs.
TerraLumen's Solution
TerraLumen moves cultivation into a protected, vertically arranged environment where growing conditions can be maintained throughout the year. Recirculating hydroponics reduces dependence on conventional irrigation, a biosecurity system removes the need for harmful pesticides, and multiple growing levels increase the productive area available within a single building footprint. Controlled lighting and temperature allow crops to be cultivated regardless of the outdoor growing season, with approximately ten annual production cycles in the final model for the crop study.
GREENHOUSES
What I Found & Why It's a Problem
Greenhouses already combine natural daylight with some protection from outdoor climate. Their greatest challenge is the relationship between sunlight and temperature. Glass admits valuable growing light but can also introduce excessive summer heat gain or substantial winter heat loss. This leads to geographic viability for greenhouses, with no production ability in winter months without an oppressive heating demand. Increasing cultivation density with stacked growing levels introduces another problem: upper plants and structural equipment obstruct sunlight from reaching the crops below, potentially decreasing production on lower levels.
TerraLumen's Solution
TerraLumen approaches the building's architecture as part of its lighting and cultivation system. Each facility uses climate and geographic specific roof geometry, building footprint, glass arrangements, insulation, and environmental controls to balance daylight availability with thermal dynamic performance. Roof and outer wall glass installation and supplemental LEDs help manage light distribution across the vertically arranged crops. The objective is to retain the greenhouse's principal advantage: access to natural sunlight, while supporting substantially greater productive density without allowing lighting and climate control costs to overwhelm the benefits.
CONVENTIONAL HYDROPONICS
What I Found & Why It's a Problem
Conventional enclosed vertical hydroponics offers precise environmental control, efficient water management, and high density production throughout the year. However, windowless facilities must provide their entire growing light requirement electrically. Artificial lighting is one of the largest energy demands in indoor hydroponics, and the heat it produces adds to the burden on climate control systems. Pumps, ventilation, and dehumidification equipment further increase electricity consumption. Conventional hydroponics relies heavily on manual planting, harvesting, and maintenance, increasing labor costs despite its capacity for year round production.
TerraLumen's Solution
TerraLumen retains the advantages of enclosed hydroponic cultivation while reducing its reliance on artificial lighting through controlled daylight admission. Its grow racks are designed to improve crop accessibility, while automated handling equipment and the Caretaker; an autonomous operations management system, can coordinate routine operations. The research evaluates TerraLumen as an integrated system, examining how its components influence one another. It also considers whether lower lighting demand, improved labor efficiency, and increased production justify the facility’s additional complexity and cost.
(Source: https://www.magnific.com/free-photo/smart-robotic-farmers-concept_17573650.htm#fromView=search&page=1& position=48&uuid=d00a5c83-d35b-44be-9724-e44198f3c1cb&track=ais_hybrid&query=%40user6702303+smart+robotic+farm)
DESIGN BRIEF
The guiding philosophy behind TerraLumen is that every part of the facility should be designed with an understanding of how it affects everything else. Improving one component does not necessarily improve the operation as a whole. A roof that admits more sunlight might reduce the need for artificial lighting, but it could also increase cooling costs during summer or allow valuable heat to escape during winter. Similarly, fitting more growing racks into a building might increase its theoretical production capacity while making the crops harder to illuminate, access, or maintain. These relationships became central to how I approached the project. Rather than selecting the most efficient equipment or arrangement for each individual task, I wanted to understand the consequences of those decisions throughout the facility. The intention was to let the research shape the design, rather than begin with a predetermined solution and work backward to justify it.
I was equally interested in the cumulative value of smaller improvements. A modest reduction in energy consumption, a simpler maintenance procedure, or a few minutes saved during a repetitive task might seem insignificant on its own. Across an entire agricultural operation, however, those improvements could produce considerable savings over the course of a year. That did not mean pursuing efficiency at any cost. More sophisticated equipment was worth considering when its benefits justified the additional expense and complexity, but there was little reason to introduce elaborate machinery where an established, simpler approach could perform the same job. Nor would reducing operating costs necessarily be worthwhile if it came at the expense of significantly lower production. The challenge was to weigh these competing priorities without losing sight of the overall objective: developing a facility in which the individual design decisions contribute to a practical, productive, and economically sound operation.
I wanted to study TerraLumen under distinctly different environmental conditions rather than select locations where the concept would have the greatest chance of performing well. Phoenix, Arizona, was chosen for its intense sunlight and hot desert climate. Although abundant sunshine presents an opportunity to reduce artificial lighting, the extreme heat also makes controlling indoor temperatures considerably more challenging. Seattle, Washington, offered an interesting contrast. Its relatively mild maritime climate experiences prolonged periods of cloud cover, particularly during winter, making diffuse daylight more important than direct sunshine. These two locations would help determine how effectively the design could make use of natural light under very different circumstances, and whether the energy savings justified the associated demands on climate control.
I originally considered three study locations, but realized that Seattle could not adequately represent every type of temperate climate. Having lived in Kansas City, Missouri, I was familiar with the region's hot, humid summers, freezing winters, severe thunderstorms, and occasional snow and ice. Unlike the more persistent conditions found elsewhere, Kansas City experiences a wide variety of weather extremes throughout the year, making it a valuable fourth study location. Kiruna, Sweden, represented the opposite end of the climatic spectrum from Phoenix, with prolonged winter cold, substantial snowfall, and extraordinary seasonal differences in daylight. During polar night, the sun does not rise at all, while summer brings weeks of persistent midnight sun. I was particularly interested in how an agricultural facility could operate through both extremes without becoming prohibitively expensive to heat or illuminate. Together, these four locations provided a demanding range of conditions through which I could examine the adaptability, practical limitations, and economic viability of the proposed design.
(Source: https://commons.wikimedia.org/wiki/File:Seattle_Kerry_Park_Skyline.jpg)(https://commons.wikimedia.org/wiki/File:Phoenix_Skyline_2025.jpg)
(https://commons.wikimedia.org/wiki/File:National_World_War_I_Museum_and_Memorial_aerial.jpg)
(https://commons.wikimedia.org/wiki/File:Kiruna_seen_from_Luossavaara_Kiruna_2026-01-08_01.jpg)
TerraLumen's four buildings were developed for substantially different climates, rather than adapting one standard warehouse design to four locations. The research examined how building proportions, roof geometry, glass, insulation, structural materials, and site conditions would affect the usefulness of natural daylight and the practicality of construction. Each building retains a single story production hall with a 20 foot wall height and a north–south long axis, but its architectural design responds to the conditions of its location. The main grow halls were also kept separate from their supporting facilities. Their dimensions describe the growing areas only; nurseries, employee facilities, utility rooms, and freight operations occupy connected northern annexes. This distinction preserves the intended cultivation space without forcing essential support functions into the rack layout.
(Grow hall: 240 × 96ft | 23,040 sq ft | 20ft eave clearance | 2.5:1 aspect ratio)
Phoenix offered more sunlight than any other location in the study, but that abundance created its principal architectural difficulty. Direct solar radiation can reduce the need for supplemental illumination while simultaneously introducing unwanted heat into the building. The research therefore focused on admitting useful daylight without exposing large portions of the interior to intense direct solar radiation.
The building's north to south orientation was selected after comparing how structural shadows move through agricultural buildings. Research referenced by ASHRAE found that an east to west arrangement can leave northern cultivation areas repeatedly shaded by the structure to their south. One multispan greenhouse study recorded differences exceeding 30% between the brightest and darkest growing positions during winter. A north to south arrangement allows structural shadows to move across the growing area throughout the day, producing more uniform daylight distribution. At Phoenix's latitude of approximately 33° north, maximizing winter solar exposure was less important than preventing persistent shading across the cultivation racks. That is why a north-south building orientation was chosen for each of the four climate studies, as all are in the northern hemishpere.
The building uses an elongated rectangular footprint, with its 240 foot dimension running north–south. Its relatively narrow 96 foot east–west width limits the distance daylight must travel from the sidewalls toward the center. The longer dimension provides additional growing area without increasing that critical cross building distance. This distinction mattered during the footprint research: increasing building length could be accommodated through repeated roof skylights, while increasing width would aggressively place more cultivation space beyond the useful reach of perimeter daylight. Ökenhallen's defining architectural feature is its asymmetric sawtooth roof. The skylight faces are oriented toward the northern sky, while the opposing, sun facing slopes remain opaque and insulated. This reduces exposure to the strongest direct solar radiation while retaining access to diffuse daylight. The configuration is not completely immune to direct sunlight, particularly when the summer sun occupies more northerly positions, but it avoids the much larger solar exposure associated with conventional horizontal skylights or broadly glass south facing roof slopes.
The research for the windows along the walls followed the same solar control principle. An early configuration gave the eastern clerestory a 4 foot vertical depth and the western clerestory 3 feet, with northern end windows and no southern end windows. The additional eastern windows were intended to capture morning daylight, while the reduced western windows limited exposure to afternoon sunlight when exterior temperatures are already high. The final architectural planning ratio is approximately 20% glass to 80% opaque wall. At the final hall dimensions and 20 foot wall height, that ratio corresponds to approximately 2,688 square feet of vertical glass. The research subsequently preferred continuous horizontal clerestories over individual punched windows. In the research comparisons, square openings could produce higher illumination immediately in front of an individual window, but long elevated bands spread daylight more consistently along the cultivation rows.
Ökenhallen's selected glass reference is HortiGlass Diffuse +AR D50, intended for a custom insulated double glazing assembly with selective near infrared rejection. Its strong diffusion helps distribute incoming radiation rather than concentrating it into a narrow beam. The research distinguished photosynthetically useful light from the broader solar spectrum: rejecting excessive near infrared radiation is desirable in Phoenix, provided that the treatment does not substantially sacrifice useful crop light. This glass was selected for its manufacturer reported light transmission of approximately 96%, along with its antireflective and solar-selective coatings, insulating cavity, and safety glazing properties.
The construction study favored structural steel frames and trusses, supported by a reinforced concrete slab and wide spread footings. The selected opaque envelope uses approximately 4 inch insulated wall panels and 5 inch roof insulation, with reference thermal transmittances of roughly 0.18 and 0.15 W/m²K respectively. The interior uses high reflectance coated steel walls and reflective standing seam roofing to maximize indirect daylight reflected back onto growing crops. The resulting building deliberately avoids the appearance and construction of a conventional transparent greenhouse. Its opaque surfaces protect the growing environment from excessive direct solar exposure, while its glass is positioned specifically to capture indirect daylight. Phoenix's architectural research also examined local energy code provisions addressing solar reflectance and thermal emittance on exterior walls and roof. This influenced the choice of light colored, PVDF coated steel cladding, which reflects more incoming solar radiation and releases absorbed heat more effectively than darker finishes. As a result, the building's exterior color and material selection became part of its thermal design to assist with reducing heat gain.
(Grow hall: 200 × 100ft | 20,000 sq ft | 20ft eave clearance | 2:1 aspect ratio)
Seattle presented a different problem. Its relatively moderate temperatures make substantial amounts of glass more practical than in Phoenix, but persistent cloud cover reduces the amount of direct sunlight available throughout much of the year. The research therefore prioritized collecting diffused daylight from a broad area of the sky rather than concentrating on one favorable solar direction.
Regngården uses a 200 foot north–south length and a 100 foot east–west width. The narrower dimension allows elevated windows to contribute toward the center of the building, while roof skylights provide additional daylight directly above the interior growing area. The combination was preferred over relying on perimeter glass alone, which would leave the most distant central cultivation rows increasingly dependent on supplemental LED light. The roof research compared conventional skylights, diffuse sawtooth roofs, gable roofs with skylight bands, and roof monitors. A tall double sided roof monitor emerged as the preferred configuration because the monitor admits light from both eastern and western portions of the sky. Under overcast conditions, that broader exposure is useful even when there is little direct sunlight.
The research consequently favors gently sloped opaque roof planes with positive drainage, rather than a completely flat roof interrupted by skylights. Seattle's approximately 39 inches of annual precipitation and frequent rainy days made standing water, roof penetrations, flashing, and long term seal reliability more important considerations than aggressive snow shedding like that of Kiruna. The wall design uses the highest glass proportion of the four facilities, approximately 35–40% glass to 60–65% opaque wall. At the final dimensions and 20 foot wall height, that represents a preliminary vertical glass amount of approximately 4,500 square feet.
The original clerestory study placed 7 foot high window bands on both east and west walls, a 6 foot band on the south wall, and a 4 foot band on the north wall. These dimensions came from the researched building geometry that documented the intended distribution: substantial openings along both long façades, additional southern daylight, and a smaller northern opening that still captures diffuse daylight. Unlike Phoenix, Seattle has less reason to heavily restrict western facing windows, because its average conditions do not impose the same prolonged extreme cooling burden. The building therefore uses more balanced eastern and western clerestories, supported by a large roof monitor that provides daylight toward the center. The glass selection also differs. Seattle's naturally diffuse sky already scatters sunlight, so imposing strong additional diffusion could reduce useful transmission without providing enough benefit in return. The selected glass is AGC Clearsight Glass with iplus 1.1 double glazing, using antireflective surfaces and low emissivity construction. The reference catalog glass achieves approximately 92% visible light transmission.
Regngården's structure uses a seismically engineered steel frame supported by reinforced concrete foundations and grade beams. The foundation design will account for local ground conditions and seismic loading. Seattle's earthquake risk required particular attention to the building's structural connections and resistance to lateral movement. The research favored ductile steel braced frames or moment resisting frames, transferring seismic forces through the roof structure and columns into reinforced concrete foundations. This approach also influenced the decision to avoid heavy precast concrete walls, which would substantially increase the building's seismic mass. The glass supports, elevated roof monitor, and their connections to the primary frame will accommodate structural movement without allowing the glass assemblies to become unintended load bearing components.
The opaque walls use approximately 5 inch insulated panels, with 6 inch roof insulation, corresponding to reference thermal transmittances near 0.15 and 0.12 W/m²K. Corrosion resistant exterior coatings and controlled roof drainage respond to the region's frequent moisture exposure. Unlike Kansas City, Seattle's window shutters do not primarily need to withstand severe hail or windborne debris. The working design therefore favors interior sliding insulated panels, protecting the mechanisms from rain while providing additional insulation when the openings are closed. The thermal closure study favored approximately 4 inch phenolic foam panels. Seattle's defining tradeoff is the increased amount of glass. Larger transparent areas admit more of the available diffused daylight but also replace highly insulated opaque construction. The research accepted greater glass exposure here because the city's climate offers a more favorable opportunity to recover that mild heating/cooling lost through useful daylight.
(Grow hall: 200 × 100ft | 20,000 sq ft | 20ft eave clearance | 2:1 aspect ratio)
Kansas City was selected to represent the difficulties of a humid continental climate. Unlike Seattle, its relatively moderate annual temperature averages conceal substantial seasonal extremes: hot, humid summers, freezing winters, heavy thunderstorms, hail, high winds, and occasional ice and snow events. The original climate research used Kansas City International Airport's 1991–2020 weather normals, which indicated approximately 36 days per year reaching at least 90°F, more than 100 freezing nights, and roughly 18 inches of annual snowfall. The building therefore could not be designed around either summer heat rejection or winter insulation alone.
Gräshuset uses a 200 × 100 foot grow hall, balancing cultivation area against the additional exterior envelope associated with a more elongated building. Its main architectural distinction is a 4:12 pitch gable roof with one continuous, north–south ridge monitor. The 4:12 pitch is approximately 18.4 degrees. It increases the surface area of a simple gable roof by approximately 5.4% compared with a flat horizontal projection, while providing a practical slope for heavy rain and winter precipitation. The research rejected unnecessarily complicated multi monitor and valley heavy roof arrangements because they would introduce more drainage intersections, structural interruptions, and glass exposed to severe weather. The single ridge monitor was retained after examining its height and potential daylight reach. With the final 100 foot wide building, the 4:12 roof rises approximately 16 feet 8 inches above the eaves, placing the ridge approximately 36 feet 8 inches above the production floor, before adding the monitor's own height. That elevation is important. Rather than placing skylights throughout the roof to reach the interior, the design uses a high central monitor to admit daylight over the middle of the building, while elevated windows on the east and west walls contribute toward the perimeter. The final geometry is approximately 36 feet 8 inches.
Gräshuset's preliminary wall to window ratio is 30% glass and 70% opaque construction, or around 3,600 square feet of vertical glass at the final rectangular wall dimensions. The wall band arrangement gave the east façade a 5 foot window depth, the west 4 feet, the south 4.5 feet, and the north 1.5 feet. Eastern exposure was favored over western exposure to collect morning light while limiting afternoon summer heat. Southern windows offered useful winter sunlight, while the much smaller northern window band provided diffuse illumination without replacing excessive insulated wall area. This was a deliberate compromise between Phoenix's solar rejection strategy and Seattle's more extensive use of glass.
The selected glass reference is Pilkington Suncool Optilam 70/35, a laminated solar control double glazing assembly. This reference glass provides approximately 70% visible light transmission, a 0.36 solar factor, and center of glass thermal transmittance of approximately 1.0 W/m²K. This glass was chosen because it was calculated to be the middle ground between lower visible light admittance and heat loss during the winter with greater subsequent heating cost. The laminated glass provides a more defensible starting point for storm resistant construction than ordinary unprotected glazing. However, the research found that the glass itself should not be the only protective measure against severe hail. An early study speculated placing insulated shutters inside the windows, similar to Kiruna's thermal closures. That arrangement could improve insulation and protect the growing area from glass breakage in a storm, but it would not prevent hail from striking and damaging the exterior glass. Kansas City's shutters were consequently moved to the exterior of both the windows and skylights. They are intended to protect the exposed glass during severe weather while also providing insulation and shading during very hot summer days. The working closure design uses approximately 4 inch phenolic foam rolling panels to protect and insulate windows as needed.
The building's primary structure uses storm hardened steel portal frames and trusses, reinforced with appropriate lateral bracing and supported by a concrete slab, grade beams, and frost depth foundations. Its roof is a hail resistant standing seam assembly, with lesser roof geometries than the more extensively windowed Seattle design. The opaque envelope uses approximately 6 inch insulated wall panels and 7 inch roof insulation, with reference thermal transmittances near 0.12 and 0.10 W/m²K. An earlier proposal used 5 inch walls and 6 inch roof insulation, but the subsequent climate comparison increased both thicknesses to account for the region's colder winter conditions. The principal design decision was to keep the building structurally straightforward. A conventional gable may be less visually distinctive than Seattle's taller monitor or Phoenix's sawtooth roof, but its simpler drainage geometry, concentrated glass, and exterior storm protection make it more appropriate for the range of conditions Kansas City experiences.
(Grow hall: 150 × 100ft | 15,000 sq ft | 20ft eave clearance | 1.5:1 aspect ratio)
Norrladan demanded the greatest research and design compared to the other buildings due to the severity of its geography and climate. Its architecture has to accommodate extreme winter temperatures, prolonged periods of little or no useful sunlight, exceptionally long summer daylight, snow accumulation, frost, and potentially difficult ground conditions. The research initially favored keeping the Arctic building close to square. For a given floor area, a compact footprint reduces the amount of exposed exterior wall compared to a long, narrow building. A building with less exterior facing walls requires less energy to maintain a heated environment opposed to a building with more external facing walls. Although the final 1.5:1 hall is not square, it remains the smallest production facility in this study. That smaller footprint is not a limitation on how much TerraLumen could produce in Kiruna. Additional facilities could be constructed if the market justified them. The research preferred that approach over indefinitely widening one building, particularly because the roof's steep pitch makes additional width expensive in structural height, construction material, and heating cost.
Norrladan uses a 45 degree gable roof, supported by a cold tough structural steel frame. The 45 degree geometry was selected after examining steeper and shallower pitched roofs, curved roof concepts, and more complicated snow shedding management arrangements. A major rejected alternative was an inverted butterfly roof, which would direct snow and precipitation toward a central valley. Although central heated gutters and drainage channels could theoretically remove accumulated snow and meltwater, the arrangement creates a concentrated collection point. A blocked drain or failed heating provision during severe winter weather would leave a large accumulation of snow load at the center of the roof or lead to water damage. A simple pitched roof was preferred because it avoids that central collection problem and allows snow to move toward the eaves. The design still requires proper snow management at ground level and around entrances.
The comparison between 40 degree and 45 degree gables was particularly important. In the Swedish snow load research, increasing the slope from 40 to 45 degrees reduced the basic pitched roof snow shape coefficient from approximately 0.53 to 0.40, a reduction of about 25% structural snow load. The steeper roof also increases the gravitational tendency for accumulated snow to slide off. This advantage comes at a cost. A 45 degree roof has approximately 8.3% more sloped surface area than a 40 degree roof over the same rectangular footprint.
For the final 100 foot building width, a simple 45 degree gable rises 50 feet above its eaves, giving a nominal ridge height of approximately 70 feet. A 40 degree roof would rise approximately 42 feet, placing the ridge near 62 feet. These are geometric roof envelope dimensions before detailed ridge construction, not final structural drawings. The research used a 3.0 kN/m² ground snow reference for early Kiruna screening. At a 45 degree pitch, the basic non drifted shape coefficient of 0.40 produces a preliminary roof snow pressure of approximately 1.2 kN/m², before structural factors and other conditions are evaluated. That is not a complete snow load calculation. Swedish structural design must still consider site specific ground snow, uneven accumulation, drifting, obstructions, wind effects, rain on snow, and situations where snow does not slide as intended. The roof's exterior uses a smooth standing seam cold roof assembly above the heavily insulated thermal envelope. Keeping the exterior surface smooth reduces obstructions for snow to gather, while separating the weather skin from the insulation provides a more controlled arrangement for moisture and temperature differences.
Kiruna's daylight study had to account for the fact that the direction and usefulness of sunlight change dramatically throughout the year. During the winter, prolonged darkness can make windows a liability because the transparent surfaces continue losing heat even when they contribute little to no useful daylight. During the summer, the midnight sun travels through northern portions of the sky, meaning that a roof designed only around southern solar exposure would fail to take advantage of part of the summer daylight resource.
The early roof research therefore explored narrow skylight strips running downslope from ridge to eave. This avoided broad transverse glass bands that could interrupt snow movement. Four strips per roof slope were initially proposed, before a spacing study recommended five narrower strips to improve daylight distribution. These strip configurations belong to the optical development stage. The later architectural direction finalized was five downslope skylight strips with insulated shutters. The underlying requirements remain the same: obtain daylight from the relevant seasonal sky directions, minimize snow traps, maintain structural strength around openings, and provide a way to insulate the glass when light is no longer worth its thermal cost.
Norrladan's final wall to window ratio is approximately 20% windows to 80% opaque construction, equivalent to around 2,000 square feet of vertical windows at the final hall dimensions and 20 foot wall height. The clerestory study was substantially more conservative. It uses 2.5 foot high bands on the east and west, a 3 foot southern band, and no northern wall windows, resulting in approximately 10% vertical windows in the geometry. That arrangement was developed primarily to limit winter heat loss. Norrladan's glass reference is AGC Clearsight with iplus 1.1 triple glazing, using two argon filled insulating cavities and low emissivity coatings. The selected reference glass provides approximately 85% visible light transmission. Quadruple glazing was considered and rejected as the preferred starting point. A fourth permanent pane might improve thermal performance but would reduce daylight transmission whenever the windows were open. The project instead favored triple glazing combined with movable insulation, allowing the transparent areas to be thermally protected only when necessary.
The insulated shutters, informally named Blast Doors during development, became one of Norrladan's most detailed architectural components. They are intended to cover both windows and skylights, allowing transparent surfaces to operate more like insulated construction when closed. The earliest concept considered panels almost as thick as the surrounding building envelope. While this offered strong insulation, it would create unnecessarily heavy moving assemblies, particularly on sloped roof skylights where guides, support frames, and drive mechanisms must carry the moving weight. The research subsequently favored a 5 inch phenolic foam sandwich panel with lightweight metal skins. Phenolic insulation offered a lower thermal conductivity than the PIR foam considered earlier, allowing a thinner shutter without abandoning the intended thermal performance.
The mechanism is based on a sliding panel with a cam assisted final sealing movement. During most of its travel, the shutter remains clear of the seal. At the end of the closing stroke, the guides draw the panel toward its frame, compressing a replaceable EPDM or silicone perimeter gasket. This avoids dragging a compressed seal across the entire travel length, reducing friction and wear. The design also retains a small enclosed air cavity, approximately 1–2 inches, between the glass and the insulated shutter. The panel does not contact the glass directly. The enclosed space provides additional thermal separation, while the compressed perimeter gasket limits uncontrolled air movement. The insulation study compared 5 inch and 8 inch phenolic panels under a conceptual −31°F exterior and 72°F interior condition. Using the glass areas from the earlier architectural model, the 5 inch closures produced a calculated combined conductive heat loss of approximately 1.50 kW, compared with 1.00 kW for the 8 inch alternative. The thicker version would therefore save approximately half a kilowatt under that specific condition, but at the expense of substantially larger moving panels. This did not justify retaining the heavier design. Hence why thinner phenolic insulation was chosen because it delivers the same insulation capabilities as the thicker PIR insulation.
The research also examined modular rather than enormous single piece closures. An illustrative 2 × 10 foot shutter section was estimated to weigh approximately 40–60 pounds, depending on its construction. Smaller sections would be easier to support, guide, seal, and replace than a single panel spanning a large roof aperture. These shutters are not intended only for polar night. They can also be used during shorter winter days when incoming daylight is insufficient to justify the heat lost through exposed glass, and during summer when the building requires control over excessive daylight or an uninterrupted dark period for a particular crop.
Norrladan's foundation study considered the possibility of peat, fill, glacial till, boulders, and deeper competent material. Removing large amounts of unsuitable soil and replacing it beneath the entire facility could become expensive, especially if the depth to competent ground varies substantially. The preferred conceptual foundation is therefore pile supported reinforced concrete caps and grade beams, transferring structural loads to suitable till or bedrock. The research considered driven precast piles, drilled steel piles, and rock socketed alternatives. No particular pile type, depth, or quantity was finalized because those decisions require actual site borings. A conventional shallow foundation could remain appropriate where competent ground is accessible, but extensive full footprint excavation was not adopted as the default approach for this study.
Norrladan has the thickest opaque envelope of the four facilities: approximately 8 inch insulated metal panel walls and 8.7 inch roof insulation, with reference thermal transmittances near 0.09 and 0.08 W/m²K. The structural steel frame is designed independently of the insulated cladding. Cold toughness rated steel, suitable connections, longitudinal bracing, and the separation of the weatherproof roof skin from the main thermal envelope are central to the architectural concept.
(Schematic Rendering)
Each grow hall includes a connected northern annex containing its nursery, employee facilities, utility rooms, and shipping operations. Earlier studies considered separate nurseries and more extensive service buildings for scaled up operations, but these arrangements were not needed for the primary study. The nursery occupies the northwest exterior corner, where its windows can admit daylight without placing the annex along the main grow hall's southern exposure. The nurseries were kept lower and wider rather than arranged as tall propagation towers like that of the main grow hall. Their operating footprints are 1,650 sq ft in Phoenix, 1,380 sq ft in Seattle, 960 sq ft in Kansas City, and 810 sq ft in Kiruna. The nurseries for each location were designed to be scaled down versions of the main grow hall they are attached to in relation to its overall grow capacity. Each uses the corresponding building's climate specific envelope approach and shares its central support facilities. Other annex rooms include a combined electrical and supervisory equipment room, a shared mechanical and plumbing room, a bathroom with handwashing facilities, and a small employee breakroom. All are accessed from the corridor rather than requiring workers to cross the production area for routine necessities.
TerraLumen maintains positive HVAC pressure to limit infiltration of outside air, insects, and airborne contaminants. Three controlled airlocks separate personnel, freight, and nursery access, with downdraft airflow at entry points providing additional contamination control. Employees wash their hands and change into dedicated boots before entering the main grow hall. The nursery has a separate personnel airlock and direct seedling transfer into the grow hall. This arrangement reduces cross contamination without requiring separate quarantine rooms or additional maintenance corridors.
The loading dock serves incoming and outgoing shipments, separated by scheduling and handling procedures. Incoming materials are inspected, stripped of unnecessary packaging, and transferred onto clean, designated internal pallets or containers before entering the grow hall through the freight airlock. Exterior pallets and delivery equipment remain in Shipping, outside of the main grow hall. The airlocks use controlled sliding doors and maintain the HVAC positive pressure boundary. Harvested crops exit through the same controlled route in reusable bulk containers. Site planning accommodates a 53-foot trailer and approximately 135-foot truck court, pending vehicle maneuvering verification.
(Schematic Rendering)
Each grow hall uses 6 × 6 ft Grow Deck racks arranged in continuous north–south rows, with racks positioned end to end without unnecessary gaps. Moving from west to east, the layout alternates between 4 ft clear aisles and 6 ft rack lanes, maintaining the same 4 ft clearance along every perimeter wall. A single 4 ft wide east–west cross aisle divides the hall near its midpoint, providing access between rows without traveling their full length. Each rack stands on lockable swivel casters for repositioning, with releasable, flush mounted floor anchors available where additional structural or seismic restraint is required.
The established production plans specify the following rack quantities for each facility:
Ökenhallen
Main Grow Hall:
23,040 sq ft
Planned Racks:
420
Regngården
Main Grow Hall:
20,000 sq ft
Planned Racks:
372
Gräshuset
Main Grow Hall:
20,000 sq ft
Planned Racks:
264
Norrladan
Main Grow Hall:
15,000 sq ft
Planned Racks:
144
(Source: https://unsplash.com/photos/teal-led-panel-EUsVwEOsblE)
Caretaker is the central supervisory computer responsible for operating and monitoring each TerraLumen facility 24 hours a day, 365 days a year. Every building has its own dedicated on site server, connected to a network of smaller computers, industrial controllers, sensors, cameras, and machinery. Together, they manage the growing environment, coordinate production, supervise equipment, maintain operational records, and respond to problems without requiring employees to remain on site continuously.
What makes Caretaker particularly important is its ability to coordinate systems that would otherwise operate independently. Lighting affects temperature, temperature influences irrigation demand, and equipment availability determines when certain agricultural tasks can take place. Caretaker considers these relationships when issuing instructions, using programmed operating rules, sensor measurements, and mathematical optimization to determine appropriate actions. Its decisions are recorded and checked against equipment feedback, providing a traceable explanation of what the facility was instructed to do and whether those instructions were successfully carried out.
The research favored a Linux based server architecture using Ubuntu Server, with individual software applications handling specific responsibilities under a unified Caretaker interface. Rather than developing every function from scratch, this approach combines established industrial control software with custom programs designed around TerraLumen's particular operating requirements. Ignition 8.3 emerged as the preferred commercial supervisory control and data acquisition (SCADA) platform, with Rapid SCADA retained as an open source alternative. The selection remains conditional on licensing, compatibility, and integration testing.
Caretaker Core acts as the coordinating authority, while the SCADA platform provides the connection to industrial equipment. Python and Google OR-Tools handle calculations that involve several competing requirements, such as selecting operating schedules that satisfy crop needs without unnecessarily increasing electricity consumption. PostgreSQL preserves equipment information and administrative records, while the historian makes it possible to examine how conditions have changed over hours, days, or entire growing cycles. The software is designed to operate locally. An internet interruption should not stop cultivation or environmental control, although remote administration and external notifications may be temporarily unavailable.
Caretaker does not directly operate every motor, pump, valve, and light fixture from a single computer. Instead, it delegates instructions to smaller controllers distributed throughout the building. These controllers communicate with the central server, operate their assigned equipment, and report whether the requested actions have been completed. The leading industrial controller candidate is the AutomationDirect Productivity1000 P1-622 programmable logic controller (PLC). The research favored sharing a controller among approximately four to eight Grow Deck racks, subject to available connections, wiring distances, and the final equipment configuration. This avoids unnecessarily installing a complete industrial PLC on every rack while still allowing individual racks to be monitored and controlled.
Each rack also requires local control electronics for its movable platforms, lighting circuits, sensor inputs, and mechanical safety devices. Other specialized controllers are responsible for equipment such as HVAC machinery, irrigation pumps, nutrient preparation, electrical distribution, and robotic systems. Caretaker coordinates their operation, but those controllers retain responsibility for immediate equipment protection. Communications use established industrial technologies rather than a proprietary network developed exclusively for TerraLumen. The researched architecture includes industrial Ethernet, RS485, Modbus RTU, Modbus TCP, OPC UA, and MQTT, selected according to the requirements of connected equipment.
Modular input/output hardware connects physical sensors and actuators, while networked cameras communicate separately through Power over Ethernet connections. This separation is particularly important during equipment failures. If Caretaker temporarily loses communication with a rack, its local controller can preserve safe operating limits instead of abandoning control of the equipment. A malfunctioning controller or disconnected sensor can also be identified without necessarily disrupting the rest of the growing hall.
Caretaker depends on continuous measurements to understand what is happening inside the building. The research therefore examined affordable industrial sensors that could be installed throughout the facility without making the monitoring infrastructure prohibitively expensive.
Several specific products were identified as leading candidates:
One particularly important decision was providing a dedicated PAR sensor for every cultivation level. With four levels per Grow Deck rack, Caretaker receives four separate measurements rather than assuming sunlight reaches every plant equally. The DFRobot SEN0641 was investigated because of its comparatively low cost, RS485 connectivity, and IP67 environmental protection. The DFRobot SEN0641 measures natural and supplemental lighting at each growing level, allowing Caretaker to adjust LED output as sunlight changes. The SEN0438 monitors temperature and humidity, providing the environmental data needed for accurate HVAC control. Both sensors offer affordable, reliable monitoring through RS485 communication.
Elsewhere, additional instruments measure air pressure, airflow, CO₂ concentration, water movement, reservoir levels, nutrient conditions, electrical consumption, and machinery operation. Position switches and motor feedback tell Caretaker where equipment is located and whether movement has completed successfully. Water flow and pressure measurements help identify blocked lines, abnormal consumption, and possible leaks before they become widespread problems. Cameras provide another source of information that conventional instruments cannot capture. Reolink and Amcrest PoE cameras were examined for observing crops, equipment, and operational areas.
Rather than installing an arbitrary number of cameras, the research emphasized determining their placement through actual visibility. Mature foliage, rack structures, and the spacing between cultivation levels all affect how much of the growing environment a camera can observe. Caretaker also monitors the monitoring equipment itself. A sensor that suddenly reports an implausible temperature, disappears from the network, or consistently disagrees with nearby instruments can be flagged for inspection. Historical records help distinguish an actual change in conditions from a faulty measurement, preventing unnecessary adjustments based on unreliable information.
One of Caretaker's most demanding responsibilities is coordinating supplemental LED lighting with the sunlight entering the grow hall. Instead of operating every LED fixture on a fixed schedule, Caretaker measures the available light at each cultivation level and calculates how much additional illumination is necessary to satisfy the crop's daily light requirement. This becomes especially valuable when sunlight reaches the upper levels of a rack but leaves the lower levels shaded. Caretaker can reduce supplemental LED lighting where natural light is sufficient while maintaining greater output elsewhere. It also tracks accumulated daily light integral (DLI), allowing lighting decisions to account for what the plants have already received rather than responding only to the conditions at that moment.
Those lighting decisions affect the building's climate. Reducing electrical lighting also changes the amount of heat released into the growing environment, which can influence heating or cooling demand. Caretaker coordinates these interactions with the HVAC equipment, considering actual temperature, humidity, available daylight, and the efficiency of the mechanical systems. Its environmental responsibilities also include maintaining positive building pressure and supervising ventilation, air circulation, dehumidification, and CO₂ conditions. Separate nursery controls allow younger plants to receive their own environmental conditions without requiring an entirely independent supervisory computer. Water and nutrient delivery follow a similar feedback process.
Caretaker monitors prepared nutrient solutions, reservoir conditions, and delivery measurements, then coordinates pumps, valves, and dosing equipment through their local controllers. By comparing commanded operation against actual measurements, it can identify an underperforming pump, unexpected pressure loss, or dosing irregularity rather than simply assuming the equipment has performed correctly. The same supervisory network controls climate specific architectural equipment, including Kansas City's protective storm shutters and Kiruna's insulated Blast Doors. Their operation must account for appropriate environmental conditions, mechanical position feedback, and independent safety limitations.
Each Grow Deck rack contains four vertically arranged cultivation platforms whose positions can be adjusted through powered mechanisms. Caretaker determines when adjustments are required and sends instructions to the rack's local controller. Before allowing movement, the equipment must verify relevant safety conditions, including platform position, travel limits, mechanical restraints, and whether movement could interfere with workers or nearby machinery. Because the racks stand on lockable casters and use releasable floor anchors, Caretaker must also accommodate equipment that can be repositioned for maintenance. Persistent rack identification and configuration records allow the supervisory system to recognize equipment after relocation or reconnection.
Robotic equipment operates through a comparable division of responsibility. Caretaker determines which tasks need to be completed and coordinates their timing, while individual robots retain their onboard navigation and collision prevention functions. A robot's battery condition, operating status, assigned task, and availability can influence when work is scheduled or whether another machine should be assigned. This gives Caretaker a broader understanding of production than an individual robot or machine possesses. It knows which racks contain crops approaching harvest, what equipment will be required, and whether a scheduled operation conflicts with maintenance or another activity in the same area.
Caretaker maintains a continuous record of crop progression, connecting nursery schedules with the main grow hall's cultivation cycles. Rack occupancy, crop age, anticipated transfer dates, and harvest readiness are used to prepare upcoming operations and coordinate the machinery needed to complete them. Although TerraLumen relies primarily on robotic equipment, certain activities still require temporary human labor. Caretaker uses the production calendar to identify those requirements in advance and notify administration of the anticipated dates, staffing needs, and equipment availability.
Nursery transfers, harvesting, and other scheduled activities can therefore be arranged around the crop cycle instead of waiting until additional workers are urgently needed. Caretaker also coordinates routine production interruptions with other operating requirements. Equipment scheduled for maintenance can be excluded from task assignments, and activities requiring access to the growing hall can be arranged to avoid unnecessary conflicts with machinery.
Caretaker maintains awareness of the building's security conditions through access control equipment, door position sensors, airlock status, intrusion alarms, and surveillance cameras. Authorized personnel receive appropriate access permissions, while unusual entry activity or unsecured controlled areas can generate notifications for administration. The central dashboard provides administrators with a view of current building conditions, equipment availability, production progress, and outstanding problems.
Authorized users can review historical measurements, acknowledge alarms, and issue permitted operating commands without needing to be physically present at the facility. Accountability was an important part of the software architecture. Caretaker records not only sensor measurements but also the instructions issued to equipment, confirmation of completed actions, changes made by personnel, and responses to abnormal conditions. These records make it possible to investigate why a decision was made, determine whether equipment behaved correctly, and identify performance changes that might otherwise go unnoticed.
Caretaker is also responsible for identifying when equipment needs attention and coordinating the appropriate response. Instead of relying exclusively on fixed calendar reminders, its maintenance records combine prescribed service intervals with actual operating hours, diagnostic information, and the history of previous repairs. A pump that begins drawing unusual power, for example, may warrant inspection before it stops working. A temperature sensor that repeatedly disagrees with surrounding instruments may need recalibration. Repeated communication failures from a rack controller can indicate an electrical or networking problem rather than a problem with the crop itself.
Maintenance scheduling covers the building's technical infrastructure as well as its agricultural equipment. IT support is responsible for servers, networking, software services, and connected computers. Other service categories address robotics, electrical distribution, HVAC equipment, mechanical assemblies, plumbing, pumps, valves, and instrumentation. For noncritical problems, Caretaker generates a work order containing the equipment identification, relevant measurements, fault history, and required service. Administration receives the request for review and coordination with the appropriate contractor. Critical failures follow a different procedure.
Caretaker initiates a request to the designated emergency service provider and simultaneously alerts administration. If the contractor fails to acknowledge the request within the agreed response period, the system escalates the problem to a backup provider. This allows urgent repairs to be initiated without requiring an employee to remain on call for routine building supervision. Caretaker's own reliability is included in the maintenance program. An independent monitoring device checks whether the central server and its communications remain responsive. If Caretaker becomes unavailable, this device can notify IT support rather than depending on the failed server to report its own condition.
Caretaker distinguishes routine operating problems from events requiring immediate protective action. A disconnected sensor may require a maintenance ticket, while a significant water leak could require affected valves or pumps to be shut down. The response depends on the severity of the condition, the equipment involved, and the potential consequences of continued operation. Electrical outages introduce another responsibility. Caretaker monitors an emergency generator, fuel availability, electrical demand, and the status of essential equipment.
It coordinates operating priorities during the outage, while independent electrical protection and transfer equipment maintain the required safety functions. The research deliberately separates Caretaker's supervisory authority from certified life safety protections. Fire alarms and other applicable emergency systems must remain capable of operating independently, with approved monitoring services responsible for contacting the appropriate emergency authorities. Caretaker receives the relevant event information, records the incident, notifies administration, and coordinates permitted equipment responses. This distinction also applies throughout the building. Local motor protections, mechanical interlocks, emergency stops, and other essential safeguards cannot depend exclusively on instructions from the central computer. If Caretaker fails, those protections must continue functioning independently.
Caretaker's architecture was developed around the objective of operating independent facilities with limited permanent staffing, without sacrificing continuous monitoring or timely maintenance response. The selected approach combines one central supervisory computer per building with distributed industrial controllers, specialized software, comprehensive instrumentation, and independent safety provisions. The research establishes the preferred technologies and intended operating behavior; final controller groupings, software licensing, sensor calibration, camera placement, and equipment integration remain subject to physical validation and commissioning.
TerraLumen's cultivation research explored three rack designs: Grow Deck, Carousel, and Trellis. Each was developed for a different approach to growing and handling crops within the climate specific buildings. All three used the same four foot aisle standard, allowing their physical arrangements and operating requirements to be studied consistently. The original research program considered separate facility scenarios for each rack family and its appropriate crops. The final comparative study was subsequently narrowed to Grow Deck and Genovese basil across all four locations, keeping the cultivation method consistent while examining differences in climate, energy demand, production, and operating costs.
Grow Deck
The Grow Deck uses horizontally stacked cultivation surfaces intended for taller crops or crops that can be grown at relatively high planting densities. Its development focused on combining multiple growing levels with practical access to the plants, their roots, and the equipment beneath each deck. The final configuration has a 6 × 6 ft cultivation footprint and four productive decks. Each deck contains six independently sliding 2 × 3 ft trays, arranged to provide 54 basil planting positions per tray. This produces 324 positions per deck and 1,296 positions per rack.
There is a four point cable lifting arrangement with a central high mounted electric motor that provides vertical adjustment for each deck controlled by Caretaker, allowing for easier access during transplanting and harvesting. The cultivation trays sit in approximately one to two inches of circulating water nutrient solution. A major part of the Grow Deck research concerned daylight obstruction between stacked surfaces. Increasing the number of decks provides more growing area, but also reduces the amount of natural light available to lower levels.
The design therefore requires supplemental lighting at each cultivation level in direct relation to how much natural daylight reaches that level at any given time and the Daily Light Integral of the selected crop. The Grow Deck trays use a passive cam guided sliding mechanism that allows each tray to rise out of its shallow nutrient basin before extending into the aisle. As the operator begins pulling the handle, the tray moves upward along an inclined track before transitioning into horizontal movement. A release button integrated into the handle is pressed during the outward pull, with a mechanical interlock preventing the tray from tilting until it clears the deck. Once released, the tray pivots downward under controlled gravity, depositing its harvested plants into a collection bin below. Pushing the tray back inward engages a fixed cam along the deck's edge, progressively returning it to its horizontal position before the spring loaded latch automatically secures it. This allows the complete harvesting motion to be performed through a single pull, button press, and push, with a design target of approximately five seconds per tray.
Carousel
The Carousel approaches vertical cultivation through movable growing shelves. Instead of requiring a worker to reach every cultivation position at its installed height, the shelves can be repositioned to bring the necessary section of the rack within working reach. An important distinction in the design is that the Carousel does not continuously rotate during cultivation. The shelves normally remain stationary and move when commanded for planting, inspection, harvesting, cleaning, or maintenance. This avoids making constant mechanical movement a greater maintenance expense. The research also investigated how to supply nutrient solution and electrical connections to moving shelves. Unlike stationary cultivation decks, the Carousel requires these services to accommodate movement without interfering with the shelf mechanism. Its development consequently included mechanical drives, shelf supports, fluid distribution, wiring arrangements, and accessible service components.
Trellis
The Trellis was developed for crops that require vertical growing space and structural support, particularly climbing and fruiting plants. Rather than concentrating cultivation into horizontal trays, the design uses upright structural members and overhead supports to accommodate plant growth and the weight of developing produce. The research examined a 12 foot high rack arrangement with six-foot structural bays and approximately three feet of overall depth. Four foot aisles provide access along the growing rows. An important feature was the intermediate use of removable horizontal support mesh for heavier fruiting crops. The mesh could provide additional support where required without permanently restricting the rack to that crop type. Removing it would allow the structure to accommodate plants grown using conventional trellising wires or other appropriate supports. The Trellis research also considered how irrigation, drainage, lighting, sensors, and maintenance access could be incorporated without obstructing plant growth or harvesting operations.
(Source: https://paintworks.nyc/)
TerraLumen uses a centralized, recirculating hydroponic network to supply water and nutrients throughout each facility. Water returning from the cultivation racks passes through filtration and UV treatment before its nutrient concentration and pH are corrected for reuse. The nursery and production hall share this infrastructure, located in the northern service annex. Caretaker oversees water distribution, nutrient dosing, circulation, and replenishment, using sensor feedback to maintain the conditions required by the crop.
The Grow Deck uses shallow nutrient pans beneath its removable planting trays. Roots rest in approximately 1–2 inches of circulating solution, while the trays themselves remain free of plumbing connections. Each cultivation deck has independent supply and return plumbing, with flexible connections accommodating vertical deck adjustments. Mesh root containment and flow channels beneath mature root systems help prevent restricted circulation. Caretaker monitors water levels, flow, and abnormal losses at the rack and deck level.
Carousel uses automatic dry break docking manifolds to supply its moving cultivation carriers. When a carrier needs to move, Caretaker stops irrigation, relieves pressure, allows drainage, and verifies that the connections have disengaged before authorizing movement. Once the carriers return to their growing positions, the manifolds reconnect and irrigation resumes after flow and leak checks. This avoids flexible hoses traveling continuously with the rotating mechanism.
Trellis uses pressure compensated, anti drain drip emitters to irrigate individual root containers. Excess solution drains into sloped collection gutters and returns to the central network. Caretaker adjusts irrigation timing and duration using flow, pressure, substrate moisture, and drainage measurements.
The nutrient management system monitors pH, dissolved oxygen, solution temperature, reservoir levels, and circulation. Chemical measurements are concentrated at central or zoned monitoring points, while individual racks use flow, pressure, and leak sensors to verify delivery. Caretaker uses these measurements to regulate fertilizer dosing, pH correction, and water replenishment. It can also identify abnormal consumption or circulation within a particular rack or irrigation zone, allowing problems to be investigated without inspecting the entire facility. For Genovese basil, the research adopted a reference nutrient formulation containing approximately:
150 mg/L nitrogen ● 31 mg/L phosphorus ● 194 mg/L potassium ● 67 mg/L calcium ● 17 mg/L magnesium ● 35 mg/L sulfur
These are reference concentrations rather than fixed dosing requirements throughout every growth stage.
One of the challenges in designing TerraLumen's water system was finding a practical way to supply hundreds of movable Grow Deck racks without filling the production hall with separate pumps, reservoirs, and treatment equipment. I compared several arrangements before settling on centralized water preparation and treatment, supported by smaller irrigation zones that can operate independently. This keeps the main equipment accessible for maintenance while allowing the nutrient solution to be managed consistently throughout the building.
Variable frequency drive pumps move the prepared solution through main supply lines that branch into individual growing zones. Each rack connects to the distribution network through standardized plumbing fittings, with separate supply and gravity return lines serving its four cultivation decks. Water from the upper decks never drains directly into those below, preventing loose roots, debris, or accumulated residue from passing between growing levels. Individual decks can also be isolated for servicing without interrupting the entire irrigation network. The racks were designed with maintenance and mobility in mind. Water supply, drainage, flushing connections, and leak containment are grouped within a lower service channel, called the "Wet Spine" the first part of a two part system, while the second part consists of electrical wiring and communication cables follow separate protected routes suspended above the racks, this is called the "Dry Spine". Quick disconnect plumbing connections allow racks to be repositioned or removed for maintenance without cutting pipes or permanently attaching them to the building.
(Source: https://www.lyinegroup.com/why-irrigation-uniformity-matters-in-commercial-hydroponics.html)
Keeping nutrient solution in circulation reduces the amount of freshwater and fertilizer needed for each growing cycle, but it also introduces the possibility of contaminants spreading through shared plumbing. The design needed to balance the simplicity of centralized treatment with the ability to isolate problems before they affect the entire crop. I considered individual reservoirs for every rack, smaller shared circulation systems, and a single building wide reservoir. Independent reservoirs would have multiplied the number of pumps, sensors, and treatment components, making maintenance unnecessarily complicated.
At the opposite extreme, one unrestricted reservoir would be easier to manage mechanically but could allow contaminated water to circulate throughout the facility. The selected arrangement uses central treatment equipment with separate distribution zones that can be isolated when necessary. Returning nutrient solution first enters a collection reservoir, separate from the prepared water supply. From there, filtration removes suspended material, loose roots, and other debris before the water passes through UV treatment to reduce microbial contamination. The treated solution is then evaluated and adjusted before returning to the clean supply network. Keeping untreated return water separate from the prepared solution means it can be filtered, treated, and checked before being used again. It also gives the system a way to isolate an affected growing zone for maintenance or suspected contamination without shutting down irrigation throughout the building.
The nutrient preparation equipment is concentrated in the northern utility annex, keeping chemical storage, mixing, dosing, and the main reservoirs outside the main grow hall. Central storage tanks and metering pumps supply the required nutrient concentrates, which are blended with treated water before entering the irrigation network. The important distinction is that plants do not consume water and nutrients at identical rates. As crops grow, their roots absorb dissolved minerals while water is lost through uptake and transpiration. Replacing that water with more fertilizer solution every time would gradually change the concentration of the circulating nutrients.
Instead, water replenishment and nutrient dosing are managed separately. Electrical conductivity measurements indicate the overall concentration of dissolved nutrients, while pH sensors monitor acidity. Caretaker uses these readings alongside reservoir levels and operating requirements to determine whether the solution needs more water, additional nutrients, or a pH correction. Temperature, dissolved oxygen, and circulation measurements provide further information about the condition of the solution. This allows the facility to maintain consistent growing conditions without repeatedly draining and replacing water that can still be treated and reused.
Recirculation continues throughout normal production, but water management also plays a role when one crop cycle ends and the next begins. After harvesting, recoverable nutrient solution can be transferred into isolated holding tanks before the cultivation equipment is washed. Separating this solution from the cleaning process prevents detergent, loosened organic material, and other wash down contaminants from entering the nutrient reserves. Retained solution can then be treated, checked, and rebalanced before being returned to cultivation.
Water recovered from the HVAC system follows a separate route. As plants transpire, moisture enters the growing hall's air and is subsequently removed by the dehumidification equipment. Rather than discarding that condensate, the design collects it for treatment and reuse. Treated collected moisture can replace part of the fresh water supply, while the nutrient solution is corrected according to measured crop consumption. Caretaker coordinates replenishment and nutrient dosing to account for recovered water, plant uptake, and system losses. This was an important consideration because a substantial portion of the water taken up by the plants eventually returns to the air. Recovering that moisture connects the building's climate control and irrigation systems, reducing the demand for new municipal water.
Cleaning presented another challenge because of the number and arrangement of Grow Deck racks. Each rack contains four growing levels with sliding trays, structural supports, plumbing, and numerous surfaces that can collect nutrient deposits or plant residue. Cleaning hundreds of these racks by hand after every harvest would demand considerable labor and reduce the time available to prepare for the next crop. I considered manual pressure washing, mobile cleaning robots, and equipment designed to wash individual racks. Each option introduced its own complications, particularly when it came to overall turnover time. The selected approach uses a fixed industrial wash down system that cleans the main grow hall as a whole.
TerraLumen's synchronized cultivation schedule makes this practical. At the end of a growing cycle, the entire hall can be cleared of plants, allowing the washing equipment to operate without working around crops at different stages of development. Cleaning becomes part of the building's regular operation rather than a separate maintenance project requiring an extensive temporary workforce.
Rotating Overhead Washing Assemblies
(Conceptual Rendering)
The main washing equipment consists of large rotating assemblies mounted near the production hall ceiling. Their arrangement resembles industrial ceiling fans, although their primary purpose during wash down is to distribute water rather than circulate air. Each assembly carries several radial spray arms fitted with nozzles that direct high volume water jets across the surrounding area. As the arms rotate, the spray sweeps over racks, cultivation trays, floors, and exposed structural surfaces. Wider spray patterns provide general coverage, while concentrated jets help dislodge loose roots, nutrient residue, and other accumulated material. The equipment was designed around the hall's overall layout rather than requiring the racks to remain permanently fixed in one arrangement. Because the Grow Deck racks can be repositioned, the cleaning system must continue providing useful coverage without depending on a single rack configuration.
Overhead spraying alone, however, would leave much of the equipment sheltered. The upper cultivation decks obstruct water directed toward the lower levels, and preliminary geometric studies showed that significant areas would receive inadequate direct spray coverage. To address this, the design includes additional nozzles positioned to direct water between the cultivation levels. These supplement the ceiling assemblies, reaching the undersides of decks, tray supports, and other surfaces that would otherwise remain protected from the overhead jets.
Centralized Washing Equipment
The washing system uses dedicated plumbing connected to equipment in the northern utility annex. Heated water is distributed through a separate manifold, with booster pumps supplying the flow and pressure required by the rotating spray assemblies. Detergent is stored in a central tank and introduced through a metering pump, avoiding the need for workers to mix cleaning chemicals throughout the building. Motorized valves control when the system uses clean water or detergent solution, while separate washing zones allow different parts of the hall to be cleaned in sequence. Dividing the hall into washing zones was an important decision. Operating every spray assembly simultaneously would demand considerably more water and pumping capacity. Cleaning selected areas in sequence allows the active nozzles to maintain the required pressure without installing oversized equipment to serve the entire building at once. The cleaning network remains separate from the nutrient circulation system.
Back flow protection prevents detergent from reaching the clean water supply, while floor drains collect the resulting wastewater. Reclaimed water can be used for washing where appropriate, but water containing detergent and dislodged organic material is kept out of the hydroponic reservoirs and handled through the designated wastewater system. By allowing the overhead spray assembly to operate separately in different zones, it allows a producer the flexibility to have multiple rack and crop types as well as grow cycles within one building. Giving the ability to wash down one area while still growing crops in another area, seperated by a floor to ceiling curtain to prevent overspray on the crops.
Cleaning Sequence & Drying
The cleaning process begins only after harvesting has finished and the production hall has been cleared. Mobile robots return to their charging stations outside the washing area, while the Grow Deck platforms remain in their lowered post-harvest positions. There is no reason to move the cultivation platforms unnecessarily when the hall is already being prepared for the next cycle.
The wash down research established a six stage operating sequence, with a modeled total of 120 minutes:
● Hot Water Pre-Rinse - 10 minutes: Removes loose vegetation, nutrient deposits, and surface debris before detergent is introduced.
● Heated Detergent Wash - 25 minutes: Rotating spray assemblies distribute the cleaning solution, loosening deposits from exposed surfaces.
● Detergent Contact - 10 minutes: The solution remains on the surfaces long enough to act on accumulated residue without continuous spraying.
● Hot Water Final Rinse - 25 minutes: Removes detergent and the remaining loosened material.
● Drainage - 10 minutes: Allows wastewater to leave the equipment and collect through the building's floor drainage.
● Assisted Drying - 40 minutes: Increased air circulation and HVAC dehumidification remove excess moisture from the growing environment.
Drying was included in the design rather than relying entirely on natural evaporation. Once washing has finished, the overhead rotating assemblies can operate without water to assist air circulation. Working alongside the HVAC system, they help remove moisture from the racks, trays, and surrounding surfaces. The intention is not to make the entire building perfectly dry, which would be unnecessary in a humid agricultural environment. Instead, the equipment and floor need to be sufficiently drained to prevent standing water and unwanted dripping during the next planting operation. The 120 minute wash down model fits within the single day reserved between growing cycles. That leaves additional time for inspections, equipment servicing, and preparing the racks before seedlings arrive from the nursery.
Equipment Protection & Safety
Because the main grow hall is designed for repeated washing, the surrounding equipment must tolerate the conditions created by the cleaning system. Lighting fixtures, cameras, sensors, motors, electrical connectors, and exposed wiring all need protection from water, cleaning chemicals, and the spray forces involved. Wash down rated housings, sealed connections, protected control components, and suitable equipment covers allow permanently installed infrastructure to remain in place during cleaning. Sensitive servers and other central control equipment are housed in the protected northern service rooms, away from the spray environment. Caretaker coordinates the wash down sequence, including pump operation, chemical dosing, valve positions, drainage, and drying. However, equipment safety does not depend exclusively on the central computer. Independent interlocks prevent operation when required safety conditions have not been satisfied, while emergency stops and equipment protections remain available throughout the process.
The washing machinery cannot begin its normal cycle until the hall has been cleared and the required safety conditions are confirmed. During operation, pressure, temperature, drainage, and detergent dosing measurements allow the system to recognize faults and stop affected equipment when necessary. The result is a cleaning arrangement integrated into the facility from the beginning. Instead of relying on a large crew to wash hundreds of individual racks, TerraLumen uses centralized water services and fixed washing equipment to prepare the hall between crops. This supports the project's limited staffing approach while keeping cleaning within the established production schedule.
The final Genovese basil study produced the following annual estimates for the four independent Grow Deck facilities.
Ökenhallen
Purchased Water:
258,096 US gal/year
Nutrients:
$10,500/year
Regngården
Purchased Water:
212,130 US gal/year
Nutrients:
$9,371/year
Gräshuset
Purchased Water:
154,012 US gal/year
Nutrients:
$6,760/year
Norrladan
Purchased Water:
127,067 US gal/year
Nutrients:
$3,762/year
(Source: https://www.fytechsystems.com/hydroponic-lighting-ultimate-guide/)
Integrated Environmental System
Energy efficiency in TerraLumen comes from more than choosing equipment that uses less electricity. The lighting, electrical, and HVAC systems are closely connected, with each influencing how the others perform. Sunlight and LEDs affect indoor temperatures, while the heating and cooling systems manage both that heat and the humidity created by plant transpiration. Removing moisture from the air also provides opportunities to recover heat and water for reuse. I approached the research with these relationships in mind, looking at how the systems could work together to reduce overall energy consumption while maintaining the growing conditions required by the crops. I designed TerraLumen's environmental infrastructure around these relationships. The objective was to minimize resource consumption while maintaining consistent growing conditions across all four cultivation levels.
This approach extended throughout the facility, from nursery operations and water management to Caretaker's supervisory systems, mobile robotics, and the electrical infrastructure supporting daily operations and emergency power. Each system contributes to the building's total electrical demand, and its operation can affect the performance of the others. Although the four facilities share the same cultivation architecture, their climates require different environmental solutions. Phoenix has abundant sunlight and intense summer heat. Seattle receives substantial daylight even during cloudy conditions. Kansas City experiences hot summers and freezing winters, while Kiruna faces extreme seasonal daylight variation and prolonged winter darkness. These differences influenced everything from skylights and LED operation to heat pump selection, humidity management, and annual electricity consumption.
Researching Natural Sunlight Distribution
Each Grow Deck rack measures 6 ft by 6 ft and contains four growing levels, providing 144 square feet of cultivation surface within a 36 sqft footprint. The studied arrangements provide 60,480 sqft of growing area in Phoenix, 53,568 sqft in Seattle, 38,016 sqft in Kansas City, and 20,736 sqft in Kiruna. This arrangement increases production without requiring proportionally more building area, but upper growing levels obstruct sunlight traveling toward those below. Additional skylights would not solve the problem because sunlight cannot pass through opaque trays, structural supports, or dense foliage. I initially investigated collecting sunlight outside the building and transporting it directly to individual growing levels. The research included reflective light pipes, fiber optic cables, tracking mirrors, focusing lenses, specialized sunlight collectors, and combinations of these technologies. The objective was to determine how much natural light could reach the crops, how much electricity it could replace, and whether the equipment required to distribute it would justify the savings.
Reflective Light Pipes
(Source: https://solatube.com/commercial/)
One of the first technologies investigated was tubular daylighting. These systems collect sunlight through an exterior opening and transport it through highly reflective tubes before releasing it inside the building. The Solatube SkyVault M74 was particularly interesting because of its approximately 29 inch diameter tube and reported performance. Published calculations indicated approximately 3% loss of direct sunlight for every 10ft of pipe, even more so when sunlight bounces off reflective surfaces along that distance. The importance of reflective material became clear when I compared alternatives. Over a 40 ft distance, a conventional silver reflective duct retained approximately 31% of the light, while a corrugated or flexible reflective duct retained approximately 0.1%. Each time light bounced against the interior surface, some was absorbed. Even a material reflecting 98% of incoming light retains only about 82% after ten reflections, 55% after thirty, and 36% after fifty.
Highly reflective, straight tubes could transport sunlight efficiently, but TerraLumen required distribution across hundreds of racks and four growing levels. Bends, branches, and mechanisms for releasing light at different locations would introduce further losses beyond the published performance of the tubes themselves. A 2015 experiment involving a five floor building offered a promising solution. Researchers installed partially reflective cones inside a vertical light pipe, allowing controlled portions of sunlight to exit at different floors. By adjusting how much each cone reflected, they achieved approximately seven times greater illumination at lower levels under their tested conditions. Another example came from a Washington, D.C. installation where a mirror that followed the sun transported sunlight through a vertical channel approximately 98 ft long. These experiments demonstrated that sunlight could travel considerable distances and be distributed across different elevations.
However, dividing the available light reduced the amount delivered to each destination. If a tube carried 80 units of usable light to five growing zones, equal distribution would provide only 16 units per zone before further light loss that doesnt directly hit the grow area. A 2026 vertical agriculture study clarified the limitation. Its light pipe system delivered approximately 45% to 75% of sunlight entering the collector to the intended growing area, at a cost approximately 15% to 38% below the fiber optic system examined in the same study. However, the arrangement primarily served the upper level of a three level farm. The lower levels continued relying heavily on LEDs, resulting in an approximately 14% reduction in total farm electricity. Reflective light pipes transported sunlight effectively, but supplying enough light to every growing level remained the central problem.
Fiber Optic Sunlight Transport
(Source: https://www.fibreopticlighting.com/end-lit-glass-fibre-optic-harnesses)
Fiber optics offered greater flexibility because sunlight could travel through relatively compact cables toward individual racks. I investigated plastic fibers, glass or quartz fibers, commercial daylighting systems, and agricultural prototypes. Plastic optical fiber was initially attractive because of its flexibility and affordability. However, a 2026 review found that the researched plastic fibers lost light rapidly over distance. Approximately 92.7% survived the first 3.3 ft, 68% survived 16.4 ft, and only 46% remained after 32.8 ft. On average, half the light was lost after approximately 38 ft. These losses occurred inside the cable, before accounting for collection and final distribution. Carrying sunlight from roof collectors to lower growing levels across a large production hall would require considerably longer routes.
Glass and quartz fibers performed better over long distances. Commercial Parans daylighting systems demonstrated sunlight transport across approximately 98 ft, with configurations approaching or exceeding 328 ft. However, these products were primarily designed to illuminate rooms, which require far less light than commercial crop production. The connection between the collector and the cables presented another problem. One experiment attributed approximately two thirds of its light losses to gaps between individual fibers. I investigated mixing different cable diameters, using additional lenses to direct light into those gaps, and running continuous fibers without intermediate connections. These changes improved individual parts of the system but did not eliminate the combined losses and material requirements.
Published agricultural research reinforced this conclusion. One Fresnel lens, a thin lens with concentric grooves that focus sunlight, collected approximately 82.93% of the available light, but only 23.78% remained after entering and traveling through 32.8 ft of plastic fiber. Another agricultural prototype delivered approximately 16% of the original sunlight while demonstrating artificial lighting reductions of 54.3% on a sunny test day and 38.9% on a cloudy day. A separate vertical farm study reported approximately 19% to 27% annual useful plant light delivery through fiber optics. Its financial comparison indicated that fiber system installation costs would need to decrease by approximately 90% to become competitive under the studied conditions. Fiber optics could deliver sunlight to shaded crops, but the amount surviving the journey and the cost of distributing it made the proposed installation impractical for TerraLumen.
Fresnel Lenses, Tracking Mirrors, and Solar Collectors
(Source: https://inhabitat.com/skyfuels-skytrough-is-worlds-most-efficient-solar-concentrator/skyfuelskytrough/) (https://www.comsol.com/blogs/how-to-model-solar-concentrators-with-the-ray-optics-module) (https://montaukhistoricalsociety.org/fresnel-lens-relit-at-the-lighthouse/)
The next investigation focused on whether capturing more sunlight could compensate for transmission losses.
Fresnel lenses use a series of small optical grooves to concentrate sunlight into a smaller area. This could reduce the size of the cables or tubes carrying the collected light. However, strong concentration requires accurate alignment with the sun. Tracking mechanisms add motors, structural supports, controls, and maintenance, while concentrated sunlight creates substantial heat at the receiving point. I investigated ways to remove unwanted heat before sunlight entered the optical transport equipment, but these introduced additional components and opportunities for light loss.
Heliostats, which are mirrors that follow the sun and redirect its light toward a fixed target, offered another approach. One researched installation used approximately 247 square feet of collection area and additional mirrors to transport concentrated sunlight more than 230 ft into a building. The distance was impressive, but the concentrated beam still needed to be divided and distributed across the crops. Additional mirrors and distribution equipment reduced the remaining light. Large exterior collector fields would also require foundations, tracking equipment, weather protection, and maintenance.
Compound parabolic concentrators, or CPCs, were particularly interesting. These use specially shaped reflective surfaces to collect sunlight arriving from a wider range of directions, reducing the need for precise tracking. A 2025 study combined multiple CPC collectors, additional lenses, different fiber sizes, and a diffuser, which spreads light across a larger area. The arrangement produced modeled light distribution uniformity above 80%. The challenge was collecting sunlight on cloudy days. Direct sunlight arrives from one relatively small area of the sky, making it easier to concentrate. Diffuse daylight arrives from almost every direction. The laws governing how light can be concentrated limit how much of that scattered light can be focused into a small opening. This was especially important in Seattle, where clouds frequently scatter incoming sunlight.
These systems performed well for illuminating buildings, but collecting enough sunlight for intensive agriculture required large openings and overly complex distribution systems.
Hybrid Light Transport and Alternative Collectors
Several experimental systems combined focusing lenses, mirrors, reflective collectors, transparent guides, and fiber optic cables to improve overall performance. One arrangement retained approximately 76.3% of the sunlight after its initial collection stage, but only 51.4% remained after transferring it into the optical fiber bundle. Another lost approximately 36.76% of its light at the connection between two components. These results were especially important because they demonstrated how a system containing individually efficient components could still lose substantial light at its connections. The research extended to luminescent solar concentrators. These materials absorb sunlight and release it again at different wavelengths, allowing some of the light to travel through a transparent panel toward a collection point.
Their ability to use cloudy sky conditions was interesting, but the repeated absorption, conversion, and transmission processes reduced the amount of useful light delivered. Another experimental approach transported concentrated sunlight through air rather than through long cables. A 2016 study demonstrated approximately 98 ft of transmission with 50.7% measured efficiency, compared with a computer prediction of approximately 71%. The light beam widened from approximately 2 inches to 5 inches during transmission. A more complete arrangement involving additional mirrors and distribution equipment achieved a predicted efficiency of approximately 62.8%. Transporting light through the air reduced cable losses but still required precise alignment and a practical way to distribute the light evenly across the growing surfaces.
(Conseptual Rendering)
After exploring different methods of collecting and transporting sunlight, I turned my attention to making better use of the daylight that could enter the growing halls naturally. The research had shown how quickly the benefits of sunlight could diminish when it had to pass through additional equipment. Incorporating daylight into the buildings themselves offered a simpler approach, allowing the roof and wall openings to serve as part of the lighting strategy without adding extensive mechanical or optical systems. The challenge was finding the right balance for each location. Sunlight that is welcome during a Seattle winter can create additional cooling demands during a Phoenix summer. In Kiruna, the opportunity to collect daylight changes dramatically throughout the year, making insulation and heat retention especially important. These differences shaped how I considered the relationship between glazing, interior surfaces, and the surrounding climate. The aim was to make good use of natural light without creating unnecessary demands on the building's other systems.
The final approach brings together the architectural decisions and the findings from the sunlight transport research. It takes advantage of daylight through the buildings' existing designs, uses reflective interior materials to improve its distribution, and accounts for the effects of seasonal weather and solar heat. This established the foundation for the next stage of the research: selecting an artificial lighting system that could complement the available daylight and maintain consistent growing conditions throughout the year.
TerraLumen's Genovese basil production model uses a daily light integral, or DLI, of 1.67 mol/ft²/day. DLI measures the total amount of light available for photosynthesis that reaches one square foot of growing area throughout the day. Unlike the brightness measurements used for household bulbs, it measures the light plants can use rather than how bright a lamp appears to people. The system also monitors photosynthetic photon flux density, or PPFD, which measures how much plant usable light reaches a given area at any particular moment. Caretaker accumulates these measurements throughout the day to determine how much of the daily target has been supplied.
For example, if a growing level receives 0.65 of its required 1.67 units from sunlight, the LEDs provide the remaining 1.02 units. LED efficiency is measured by the amount of plant usable light produced for each unit of electricity. TerraLumen's operating model uses 3.0 µmol/J, meaning the fixtures produce 3 micromoles of photosynthetic light for every joule of electricity consumed. A micromole is a standardized count of photons, the individual particles of light. The model assumes 85% of the emitted light reaches the crop canopy, with the remainder lost through scatter, reflection, and absorption. This distinction matters because light that misses the plants still consumes electricity. Under these assumptions, supplying the entire daily lighting requirement artificially consumes approximately 0.182 kWh per square foot of growing surface. A kilowatt hour, or kWh, is the electricity consumed by a 1,000 watt device operating for one hour.
I investigated several Philips GreenPower lighting products, comparing electricity consumption, plant-usable light output, fixture dimensions, efficiency, and coverage. The GreenPower Production Module 3.2 measured approximately 59 inches, consumed 86 watts, and produced 290 micromoles of light per second at an efficiency of 3.4 µmol/J, with a 140 degree light spread. Other Production Module options included 51 watt and 64 watt versions, while some longer fixtures measured approximately 94.5 inches, exceeding the width of an individual 6 ft Grow Deck. The GreenPower Toplighting Linear offered greater efficiency, producing approximately 550 micromoles per second while consuming 142 watts at 3.9 µmol/J. These comparisons demonstrated that fixture efficiency and light distribution were more important than wattage alone.
I also investigated different fixture arrangements for illuminating each 6 ft by 6 ft growing level. One configuration positioned two fixtures overhead and four along the edges, angled inward to improve coverage across the growing surface. This arrangement helped address uneven illumination, particularly near tray edges, where insufficient light could limit plant growth regardless of brightness at the center. Based on the research, I selected the 142 watt Philips GreenPower Toplighting Linear for integration into the Grow Deck system. TerraLumen's operating calculations retain the adopted efficiency of 3.0 µmol/J and 85% canopy delivery assumptions when estimating electricity consumption.
Each of the four growing levels receives supplemental lighting independently because the upper levels obstruct much of the natural light reaching those below. The selected 142 watt fixtures are incorporated into the rack structure without interfering with sliding trays or adjustable deck positions. Electrical connections are routed through the dedicated high "Dry Spine", separate from water and nutrient plumbing. This arrangement protects electrical equipment and makes maintenance easier without disrupting the water distribution system.
Caretaker measures plant usable light at every growing level, records how much has accumulated during the day, and adjusts LED output to supply the remaining requirement. This allows different levels to receive different amounts of supplemental lighting according to their actual daylight conditions. Lighting operation is coordinated with HVAC because approximately 95% of LED electricity becomes heat within the building under the adopted environmental model. Reducing artificial lighting therefore changes both electrical consumption and the amount of heat the HVAC system must manage.
TerraLumen's annual LED electricity estimates account for each facility's cultivation area, seasonal daylight availability, and supplemental lighting requirements. The calculations use a daily light target of approximately 1.67 moles of light per square foot, an adopted LED efficiency of 3.0 micromoles per joule, and 85% canopy light delivery. Each Grow Deck contains four growing levels measuring 6 ft × 6 ft, providing 144 square feet of cultivation area per rack. The research established the electricity required if LEDs supplied the entire daily lighting requirement. Natural daylight was then incorporated to determine the supplemental lighting demand for each facility. The resulting annual budgets reflect the differences in growing area, geographic location, and seasonal sunlight availability.
Ökenhallen
Growing Area
60,480 sq ft
LED Usage w/o Daylight
3,856,023 kWh
Daylight Contribution
70.2%
Annual LED Usage
1,150,000 kWh
Electricity Rate
$0.065/kWh
Annual LED Cost
$74,750
Regngården
Growing Area
53,568 sq ft
LED Usage w/o Daylight
3,428,996 kWh
Daylight Contribution
58.6%
Annual LED Usage
1,420,000 kWh
Electricity Rate
$0.060/kWh
Annual LED Cost
$85,200
Gräshuset
Growing Area
38,016 sq ft
LED Usage w/o Daylight
2,457,719 kWh
Daylight Contribution
49.1%
Annual LED Usage
1,250,000 kWh
Electricity Rate
$0.058/kWh
Annual LED Cost
$72,500
Norrladan
Growing Area
20,736 sq ft
LED Usage w/o Daylight
1,356,439 kWh
Daylight Contribution
25.37%
Annual LED Usage
1,012,302 kWh
Electricity Rate
$0.045/kWh
Annual LED Cost
$45,554
Caretaker manages supplemental LED lighting according to available daylight, daily crop illumination requirements, and electricity pricing. Its monitoring system evaluates the lighting conditions at each growing level, allowing fixtures to operate when additional illumination is needed. To reduce operating costs, Caretaker prioritizes supplemental lighting during lower cost, off peak electricity periods whenever crop requirements permit. Its scheduling model evaluates hourly electricity prices, available lighting hours, and the remaining daily light requirement to determine the most economical operating schedule. Caretaker also prioritizes eligible equipment and battery charging during off peak periods. These electrical loads are accounted for separately from the cultivation lighting budgets. The resulting budgets account for the supplemental lighting requirements of each facility while incorporating natural daylight utilization and Caretaker's electricity cost management strategy.
(The project and research are complete; the portfolio presentation is actively being compiled and published in stages.)
SECTIONS TO COME
(Electrical & HVAC)
(Nursery, Shipping & Receiving, Processing)
(Labor, Automation)
(Cost of Operation, Revenue, Profit, Capital)
(Comparing to Other Types of Agriculture)